Product name:

Distributed power quality intelligent optimization device

listing date: 2017-11-18
Products / Related products
2017 - 11 - 21
Highlight FeaturesHigh Irms RatingHigh Ipeak RatingLow self-inductanceHigh reliability and life expectancyNon-polar技术参数Paramaters产品型号SpecificationDCLJCSY 900-700额定电容Rated Capacitance700uF(25℃)额定电压Rate...
2017 - 10 - 13
Execution standard: Meet the requirement of standard《IEC I: 60252-1-2013》《UL810-2008》《GB3667.1-2016》; Product features:low in dissipation,small inherent temperature rise,long life ...
2017 - 11 - 22
Standard:《UL810-2008》《IEC 60252-1:2013》《GB/T 3667.1-2016》.Feature: Low dissipation factor,Low temperature rise,Long service life,Excellent self-healing property,Stable capacitance,Inner explosion...
Product features

分布式电能质量智能优化装置

1, product introduction

      Distributed power quality intelligent optimization device (referred to as UPDS) is suitable for solving the distribution network exists low voltage, three-phase unbalance, low power factor and harmonic problems. The use of advanced synchronous rectification technology, with anti-voltage disturbance ability, accurate compensation, high-speed dynamic response and so on. To the distribution network voltage (120V ~ 260V) fluctuations in the user to provide standard 220V ± 3% voltage.

2, Features


Bidirectional regulation of voltage: When the input voltage of the device is between 120V ~ 260V, the output voltage is stable to 220V ± 3%, the distortion rate is less than 3%. At the same time the device supports single-phase or three-phase connection.

 

Three-phase unbalanced management: Both active and reactive power required by the user side are provided by the DC support capacitor. Based on the synchronous rectification technology, the capacitor obtains active power from the grid without injecting reactive power and unbalanced current into the grid. When the user load is asymmetric, the transformer side is still balanced three-phase output.


Seamless Bypass Switching: The Distributed Power Quality Optimizer incorporates a bypass switch that intelligently determines when power is applied to the grid, switching bypass mode or online mode. Mode switching, the output voltage amplitude, phase and input voltage exactly the same, to achieve no current switching.

 

Modular design: Taking into account the growth of the user load characteristics, the device uses a modular design. Customers can configure the capacity according to different needs, the need for expansion or replacement, the increase or decrease can be easily replaced, thereby reducing duplication of investment.

 

Structural Design: The device supports outdoor pillar installation or indoor installation, the protection grade is IP54, which can be installed on the existing poles or distribution room.

 

Communication system design: Equipment with RS232 / 485 and GPRS interface, can access the power grid SCADA system, real-time monitoring of power grid voltage, current, power and other state, to achieve the daily maintenance of equipment and management.

 

Expansion: The device has reserved a new energy interface that can accept new energy such as photovoltaic, wind power or biogas power access. The new energy power access can effectively solve the capacity shortage of distribution transformers, ease the peak of power consumption and improve the stability of power distribution.


3.technical parameters

The main technical parameters

name

parameter

Description

enter

Working phase voltage

120V~260V

Adaptable to three-phase unbalanced voltage conditions

Electrical wiring

Three-phase four-wire

TN-S bus (independent N and PE lines)

Operating voltage and frequency

50Hz


Output

Rated output voltage

380V (-3% ~ + 3%) three-phase 3P4L;

220V (-3% ~ + 3%) Single phase 1P


Electrical wiring

Three-phase four-wire

TN-S bus (independent N and PE lines)

Operating voltage and frequency

50Hz/60Hz


Operating parameters

Rated Capacity

Three-phase:0~75KVA

Multiple machines can be expanded in parallel

Simplex:0~25KVA

Multiple machines can be expanded in parallel

Performance

On-off level

≥20KHz


Full response time

<10ms


Network side current harmonic content

<5%


Network side power factor

≥0.96


Network side of the imbalance in power

<3%


Environmental conditions

Ambient temperature

-30~55


Relative humidity

<95%RH No condensation


Altitude

2000m

Above 2000m, derating 1% for every 100m lift

cooling method

Forced air cooling


Installation method

Outdoor column-mounted or wall-mounted installation; Indoor wall-mounted installation.


Communication Interface

Standard RS232 / 485 interface, GPRS interface, Ethernet interface and power line carrier

Expand ability

Up to 12 devices in parallel

Building block structure

Degree of protection

IP43, can be customized according to user requirements


noise

≤60dB 


Can work effectively

MTBF≥100,000 hours




4. product list

Installation method

Line system

Optional capacity range

Standard model products

Outdoor

3P4L or 3P3L

0~75KVA

SYICD-UPDS 0.4/10-Z

SYICD-UPDS 0.4/50-Z

SYICD-UPDS 0.4/75-Z

Indoor

3P4L or 3P3L

0~75KVA

SYICD-UPDS 0.4/10-I

SYICD-UPDS 0.4/50-I

SYICD-UPDS 0.4/75-I


5.product naming instructions

分布式电能质量智能优化装置


last:nullnext:null
Product parameters
佛山市顺德区胜业电气有限公司
Scan
access to mobile phone cloud web site
Contact us
Copyright ©2017 - 2020 Foshan Shunde District Sheng Ye Electric Co., Ltd.
犀牛云提供企业云服务
犀牛云提供云计算服务
Address: 4th Road,Lunjiao Town,Shunde Foshan City,Guangdong Provinec,China
Phone:0757—27881769
fax:+86 0755-2788 8009
Zip code:330520
Email:shengye@shengye.com
X
6

二维码管理

1

QQ设置

5

电话号码管理

  • 0757-27881773
3

SKYPE 设置

4

阿里旺旺设置

等待加载动态数据...

等待加载动态数据...

等待加载动态数据...

等待加载动态数据...

展开